I have use of a power meter today and would like to also check the power out on my ULS M-300 and VLS4.60. Do any of you know what I need to do in order to make the laser fire and run the test?
I have use of a power meter today and would like to also check the power out on my ULS M-300 and VLS4.60. Do any of you know what I need to do in order to make the laser fire and run the test?
Trotec Speedy 300 45W
Universal VLS4.60 50W
Universal M-300 50w
ShopBot PRSAlpha48
Techno LC4848
Oneway 2436
Place magnets on the door sensors. In the Control Panel, there's a system tab for checking on specs, aligning the table, etc. In the table section there should be a button for test firing the laser.
Hi-Tec Designs, LLC -- Owner (and self-proclaimed LED guru )
Trotec 80W Speedy 300 laser w/everything
CAMaster Stinger CNC (25" x 36" x 5")
USCutter 24" LaserPoint Vinyl Cutter
Jet JWBS-18QT-3 18", 3HP bandsaw
Robust Beauty 25"x52" wood lathe w/everything
Jet BD-920W 9"x20" metal lathe
Delta 18-900L 18" drill press
Flame Polisher (ooooh, FIRE!)
Freeware: InkScape, Paint.NET, DoubleCAD XT
Paidware: Wacom Intuos4 (Large), CorelDRAW X5
Ed,
Turn system on wait for the ready screen.
Press escape
use the triangle key to move the cursor down to preferences press select
move down to diagnostics press select
select alignment and raise the power to 100 percent
select KHZ and raise it to 25 or the max press select
Use magnets on the top door you may have to move them around until you get the solid green lite on the keypad.
You must not be in focus when using the power meter press the left arrow key to move the head to the upper corner.
Use the XY button to fire the beam once your meter beeps three times press the XY button again to turn off the beam.
Be sure to wear safety glasses and keep your hands out of the system when testing. The beam will be on if you are UN sure move one of the top door magnets if the red light flashes the interlock is open and the beam will not fire.
For the VLS system you need to go into the UCP and then into the system tab launch the alignment mode.
Set the power to 100 and the frequency to the max
set the time to 6 seconds and configure the magnets for the top door
Position your meter OUT OF FOCUS and then click on the Activate Laser button
Keep your hands out of the system when the laser is activated after the six seconds it will shut off depending on your meter you may have to adjust this time accordingly.
Last edited by Mike Mackenzie; 12-20-2010 at 2:52 PM.
Mike Mackenzie
Sales and Service of Universal Laser Systems